PT-C90+ Color Doppler Ultrasonic Diagnostic System

Customized: Non-Customized
Certification: CE
Scale: Medium
Color: 3D
Transport Package: CTN
Specification: small
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PT-C90+
Trademark
perlong
Origin
China
HS Code
90278099
Production Capacity
1000/Month

Product Description

PT-C90+ Color Doppler Ultrasonic Diagnostic System
product name Color Doppler Ultrasonic Diagnostic System

Display: multipositional Moving19" LCD
 
Control Second Display: 10.4" touch screen monitor
 
Power supply
 
Power: (AC) 220V±22V 50Hz±1Hz
 
Input power: 350VA
 
Safety classification
 
Protection against harmful ingress of water:
 
Protection against electric shock : Class I.
 
Degree of protection against electric shock: Type BF.
 
IPX1  the probe cable:IPX1
 
IPX7  the traducer of the probe:IPX7
 
Scope of application
 
General and Special (Vascular)
 
Programs: General checking, newborns, musculoskeletal system, Gynecology, abdomen, urology, peripheral vessels, small parts (including breasts, thyroid, testis, etc.) ,cardiac
 
Scanning mode
 
Electronic linear, electronic convex, Electronic phased array
 
Mode of display
 
Black-and-white image: B, 2B, 4B, right/left B|M, B|D, right/left PW(D), top/down PW(D), M, B mode local amplification, linear probe trapezoidal imaging, 3D reconstruction
 
Blood flow images: spectrum: B/BC, BC/B, B/D, B/C/D CFM: B|C|D, B|C|M, B|C double real-time, PW(D), CFM, CPA, Power doppler
 
Color Doppler: color mapping, Tissue harmonic imaging, image enhancing algorithm.
 
Mode of display: energy, velocity, variance (in support of velocity variance), frequency, gain
 
Display control: the size and position of the sampling box are adjustable, the emitting angle of the linear probe is adjustable.
 
Spectral Doppler:
 
Sampling volume and position are adjustable
 
PW(D) tracing supports maximum and average velocity. The threshold of the maximum velocity is adjustable. Scanning scope: above base-line, below base-line and entire scanning.
 
PW(D) sound can be turned on or off, and can be regulated in volume. Velocity measuring: in support of maximum and minimum velocity
 
Parameters for control of blood flow color images: Doppler frequency, position and size of sampling box, base line, color gain, deflection angle, wall filter, accumulative number of times, etc.
 
Color depth of display
 
Continuously adjustable
 
Focusing
 
Electronic focusing + sound lens focusing
 
Emission involves single focus, double focuses, triple focuses, and quadruple focuses
 
Continuously dynamic focusing in receiving
 
Formation of digital beam
 
Continuously dynamic focusing
 
Dynamic aperture diameter
 
Weighted sum of reception delay
 
In support of semi-moment scanning, and ±10°linear reception deflection angle
 
Multi-beam processing
 
Signal processing/Doppler sound
 
Dynamic wave filtering
 
Quadrature demodulation
 
Total gain control
 
Composite gain technology: 8-section TGC and D-AGC.
 
Low-pass filter
 
Secondary sampling
 
Acoustic output adjustment
 
Adjustable Doppler stereophonic acoustic output
 
Image processing
 
Dynamic scope variation and logarithmic compaction
 
Time filtering
 
Space filtering
 
Frame average
 
Fringe enhancement
 
Gray scale variation
 
B|M- or M-mode scanning speed
 
Linear density control
 
Scanning angle/width control
 
Image optimization
 
Upward and downward Image flipping
 
Multi-angle image rotation
 
Options for color gray-scale bar inversion
 
Combined processing of tissue and flow images
 
Resolution of black-and-white images: 1024×768×8 bits (256 gray-scale)
 
Resolution of color images: 8 bit×8 bit×8 bit color coding
 
Selection of specific images
 
Optimized items are available to choose from
 
Basic measuring and calculating functions
 
2D normal measurement: distances, angle, perimeter, area (ellipse and locus methods), volume, volume - 3-line method (length, width, height), histogram, cross-section chart
 
Basic M-Mode measurement: time, distance, heart rate, valve rate
 
Obstetric measurement
 
With 4 varieties of obstetric databases for reckoning gestation age
 
3 non-editable versions: Asian, European and American, plus 1 editable version: user-customized.
 
The gestation age can be reckoned by the information in each version on gestational sac diameter, crown-rump length, biparietal diameter, head circumference, abdominal circumference, femur length, humerus length, abdominal transversal diameter, length of vertebrae, occipital-frontal diameter, cerebellum diameter, fibula length, radius length, Cisterna Magna, inner orbital diameter, output orbital diameter, amniotic fluid index, fetal heart rate, nuchal transparency, distance and area, etc.
Obstetric report
 
Measurement and calculation of amniotic fluid index (AFI)
 
Ratio calculation (BPD/OFD, FL/AC, FL/BPD and HC/AC)
 
Fetus weight estimation
 
Reckoning the gestation age and EDD by LMP and BBT
 
Fetal biophysical score
 
Fetal growth curve
 
Andrology measurement and calculation
 
Measurement and calculation of prostate and testis
 
Calculation of predicted prostatic specific antigen (PPSA) and Prostatic Specific Antigen density (PSAD).
 
Gynaecology measurement
 
Measurement and calculation of the uterus, left ovarium, right ovarium, left folliculus, right folliculus, etc.
 
Urology measurement and calculation
 
Detection and calculation of the left kidney, right kidney, bladder, residual urinal vol, etc.
 
Vessel measurement and calculation
 
Measurement and calculation of area stenosis rate and vascular stenosis rate.
 
Multi-fetus detection and measurement
 
Detection of multiple fetuses
 
Small parts detection and calculation
 
Detection and calculation of thyroid, galactophore, masses, etc.
 
Cardiac detection and calculation functions
 
Cardiology measurement software package-contains features of analyzing and measuring aorta, mitral valve, (left/right) ventricles, etc.
 
Area stenosis percentage (% area sten), tube diameter stenosis percentage (% Diam Sten)
 
Body surface area (BSA)
 
Body mark
 
In terms of bodily function, an body mark database is divided into several parts: abdomen, andrology, cardiology, gynecology, musculoskeletal, obstetrics,

pediatric, small parts, urology, etc.
 
Screen-displayed information
 
Probe conditions, mode of display, depth, focus, dynamic range, body marks, probe position marker, acoustic output, patient conditions, name of medical agency, measured value, time and date, scale, scanning direction, gray-scale curve, current working frequency of the probe, frame frequency, B-Mode total gains, C-Mode total gains, Mode-D total gains, menu, annotations, gray-scale belt, puncture guide line, TI (thermal index), MI (mechanical index)
 
Storage
 
Probe parameter storage
 
Image storage
 
Cine loop storage
 
Measurement results storage
 
Report storage
 
Cine loop
 
Automatic cine-loop
 
Manual cine-loop
 
Cine-loop speed setting
 
Cine-loop search
 
Frame-by-frame forward/backward cine-loop
 
Gray-scale
 
256 gray-scale
 
Language interface
 
Chinese and English available
 
Function of the trackball
 
Performing various operations based on the working state and menu
 
Controlling multiple electronic scale, locating the cursor, completing measurement
 
Input/output port Achieving: USB. BW printer, CR/RW
 
VGA output port
 
DVI output port
 
Network port
 
USB port
 
Video port (for B/W printer)
 
CR/RW.
 
DICOM
 
Introduction to the probe
 
proper Transducers for research.
 
Physical Number of channels 128
 
 3.5MHzR65 multi-frequency convex probe (128 channels) , 192 crystals  
 
The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode , they have a scanning angle of 60°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
   Scope of application: examination and diagnosis of abdominal tissues, such as liver, gallbladder, spleen, pancreas, kidneys, gastro-intestinal, uterus, urinary bladder, prostate, etc.; assessment of growth and maturity of fetus in obstetric diagnosis.  
 
Endocavity probe (transvaginal and transrectal)
6.5MHzR10 multi-frequency convex probe (128 channels) , 192 crystals 
 
The probes have a frequency range between 5.0MHz-9.0MHz. In the B-Mode , they have a scanning angle of 140-158°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode. 
Scope of application: vagina, uterus, rectum, rectum wall, prostata, etc. 
Warning: Oil- and bacteria-free rubber sleeve must be added when using the probes. The probes should not be activated until going in the patient's body. 
 
7.5MHzL46 multi-frequency linear probe (128 channels), 192 crystals 
 
The probes have a frequency range between 6.0MHz-12.0MHz. In the B-Mode , they have a scanning width of 38-45. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
 
 7.5MHz multi-frequency rectal probe (128 channels), 192 crystals 
 
The probes have a frequency range between 6.5MHz-8.5MHz. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode. 
Scope of application: rectum
Capability to add different options, like DICOM, Stress Echo, Elastography, in case if customer will decide to add later. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now