Ventilator Fan for Emergency Equipment Hospital Used (PA-900B)

Type: Ventilator
Kind: Medical Equipment
Certification: CE, ISO13485, RoHS
Group: Adult & Child
LCD Display: 10.4 Inch Color LCD Display Screen
Ventilation Mode: A/C, Sippv, Ippv, Simv, Psimv, P
Samples:
US$ 4200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PA-900B
Tidal Volume
20-1500ml
Respiratory Rate
1-99bpm
(I:E) Ratio
4:1-1:4
Peep
0-10CMH2o
Trigger Sensitivity
-10-10CMH2o
Transport Package
Cartons for Export
Specification
0.55 CBM; 77 GS
Trademark
PA
Origin
China
HS Code
9019200000
Production Capacity
200 Units/ Month

Product Description

Ventilator Fan for Emergency Equipment Hospital Used(PA-900B)



Ventilator Fan for Emergency Equipment Hospital Used (PA-900B)


Common Features
Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
Pneumatically driven electrically controlled ventilator, can be used for emergency clinical resuscitation and respiratory therapy
Display: Built-in 10.4 inch color TFT fully adjustable display, able-display Pressure-Time, Frequency-Time, Pressure-Volume, Frequency-Volume and any two waveforms simultaneously on screen
Trigger Types: Pressure trigger, Flow trigger
Sigh: Ability to insert 1-8 sigh breaths in every 100 breaths, ventilation should be no less than 1.5 the tidal volume
Features built-in dual electronic flow sensors and dual respiratory modules
Power Failure Support Functions: Automatically converts-standby mode during AC power outages
Monitor Parameters: tidal volume, respiration rate, airway pressure, I:E ratio, inspiratory & expiratory status, inspiratory trigger and others
Equipped with infrared turbine flow sensor; precisely measures gas flows, stable and reliable

9 Level adjustable humidifier
Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an automatic self-calibrating sensor
Alarms: Audible and/or visual alarms for ventilation volume, tidal volume, oxygen concentration, asphyxia, airway pressure, intubation disconnection, low oxygen, power failure and other alarms, also features a alarm history query function
 
Advanced Model Exclusive Features
Equipped with professional medical grade air compressor tailored for long clinical times and low noise requirements
 
Air Compressor
Air Compressor: 220V AC±10%, 50±1Hz, 700VA, also features good protective grounding against electrical activity
Output Gas Pressure: 0.4MPa±20%
Continuous output gas flow greater than or equal to 20L/min
Instantaneous output gas flow great than equal to 60L/min

 
Specifications
Model 900B (Standard Model) 900B (Advanced Model)
Display 10.4 inch high visibility color TFT display
Ventilation Mode A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT MANUAL
Minute Volume Greater than or equal to 18L
Back-up Power Supply At least 4 hours
Tidal Volume Adjustable range: 20-1500ml, Display range: 0-2000ml
Respiratory Rate 1-99bpm
Inspiratory/expiratory (I:E) ratio 4:1-1:4
PEEP 0-10cmH2O 
SIMV Rate 1-20bpm
Inspiratory Pressure Trigger .-10-10cmH2O 
Trigger Sensitivity (flow) 1-10L/m
Inspiratory Plateau Adjustable from 0-50% of inspiratory time
Adjustable Oxygen Concentration 45-100% 21-100%
Gas Supply Requirement 280~600 kPa medical grade oxygen and compressed air supply
Pressure Limit 1.0kPa~6.0kPa
Maximum Safe Operating Pressure ≤6.0kPa
Tidal Volume Alarm Upper Limit: 10~2000ml, Lower Limit: 0~1800ml
Airway Pressure Alarm Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa
Oxygen Concentration Alarm Upper Limit: 22~100%, Lower Limit: 21~80%


Ventilator Fan for Emergency Equipment Hospital Used (PA-900B)