Hospital Baby Warmer Resuscitaire Infant Radiant Warmer with Phototherapy Unit

Type: Infant Radiant Warmer
Kind: Nicu
Certification: CE, ISO13485
Group: Baby
LCD Display: With LCD Display
Classification: Infant Radiant Warmer
Samples:
US$ 2900/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
IRW-9300B
Applications
Nicu,Operating Room
Phototherapy Unit
Yes
Modes
Pre-Warm ,Manual or Automatic
Oxygen Cylinder
No
X-ray Cassette
Yes
Tilt Angle of Bed
Stepless Adjustable
Heater Head
Adjusted
Low Pressure Aspirator
No
Transport Package
Carton
Specification
with trolley
Trademark
Perlong
Origin
China
HS Code
90189090
Production Capacity
1000PCS/Month

Product Description

Hospital Baby Warmer Resuscitaire Infant Radiant Warmer with Phototherapy Unit

Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
Set temperature and baby temperature can be displayed separately;
Horizon angle of warmer module and inclination of the bassinet can be adjusted;
The panels around bassinet can be turned outward;
X-ray cassette under the bassinet;
APGAR timer;
Timer to count phototherapy time;
Failure alarm indication;
RS232 connector.

Standard Configuration:
IRW-9300: warmer module, bassinet, main column, mobile stand, controller, I.V. Pole and tray.
IRW-9300B: based on IRW-9300, added with the phototherapy unit.
IRW-9300A: based on IRW-9300B, added with the breath resuscitation bag, infant head fixing unit, the oxygen supplying set ( the oxygen cylinders, buoy type oxygen regulator, wall type oxygen regulator),low-pressure suction.

Optional Configuration:
Disposable skin temperature sensor, Vertical height adjustment (VHA) stand and Weighing system

Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 700VA (IRW-9300)
                   AC220V-230V/50Hz or AC110-120V/50-60Hz, 750VA IRW-900B,IRW-9300A)
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Angle of heater head: 0°,30°,60° for two ways
Inclination of the bassinet: ±10°
APGAR timer: audible and visible  alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
The total irradiance Ebi on the effective surface area: ≥0.66mW/cm2 (IRW-900B,IRW-9300A)
Average value of general bilirubin radiation on the mattress effective range: ≥0.58mW/cm2 (IRW-900B,IRW-9300A)
Bilirubin uniformity of radiating on the mattress effective range: >0.4(IRW-900B,IRW-9300A)
Dominant wavelength of blue light: 400-550nm
 

Send your message to this supplier

*From:
*To:
avatar Mr. Leo
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now