Cuna Radiante Termica Hospital Baby Infant Radiant Warmer

Type: Infant Radiant Warmer
Kind: Nicu
Certification: CE, ISO13485
Group: Baby
LCD Display: With LCD Display
Medical Device Regulatory Type: Type 3
Samples:
US$ 1400/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
IRW-2000A
Classification
Infant Radiant Warmer
Applications
Nicu,Operating Room
Phototherapy Unit
Double Sides Phototherapy Radiant Box
Modes
Pre-Warm ,Manual or Automatic
Oxygen Cylinder
No
X-ray Cassette
No
Tilt Angle of Bed
No
Heater Head
No
LED Observation Light
No
Low Pressure Aspirator
No
Transport Package
Carton
Specification
with trolley
Trademark
Perlong
Origin
China
HS Code
90189090
Production Capacity
1000PCS/Month

Product Description

Cuna Radiante Termica Hospital Baby Infant Radiant Warmer 

Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
Set temperature and skin temperature can be displayed separately;
Main body is made of stainless steel;
Double sides phototherapy radiant box;
Acrylic glass bassinet;
APGAR timer;
Timer to count phototherapy time;
Failure alarm indication;
RS232 connector;
Disposable skin temperature sensor is optional.
Standard Configuration:
Warmer module, temperature controller, bassinet, phototherapy radiant box, and the stand.
Specification:
Power requirement:  AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor: ±0.2ºC         
Temperature uniformity of mattress: ≤2ºC
Dominant wavelength of blue light: 400-550nm
Timing range of blue light: 0~9999hrs 59min
APGAR timer: audible and visible  alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Average value of general bilirubin radiation on the mattress effective range:
≥250uW/cm2(the above phototherapy equipment)
≥600uW/cm2(the nether phototherapy equipment)
Bilirubin uniformity of radiating on the mattress effective range: >0.4
 