Audited by an independent third-party inspection agency
Generator | Radiography kV Range | 44 to 125kV total 41 steps |
Radiography mA Range | 30 to 500mA total 8 steps | |
Exposure Time | 0.02 to 5s total 23 steps | |
Fluoroscopy kV Range | 44 to 110kV | |
Fluoroscopy mA Range | 0.5 to 5mA continuous regulation | |
TOMO | Tomographic capability | |
Anatomical Programing | Yes | |
Power Supply | 380VAC±38VAC, 3-phase | |
Power Frequency | 50/60Hz±1Hz | |
Power Capacity | 50kVA | |
X-ray Tube | XD52-30.50/125 XD51-20.40/125 | |
Rated Voltage | 125kV 125kV | |
Rated Focal Spot Value | 1.0/2.0mm 1.0/2.0mm | |
Max Power(0.ls)(kW) | 30 (small) / 50 (big) 20 (small) / 40(big) | |
Rotate Speed (min1/rpm) | 2800 (50Hz) 2800 (50Hz) | |
Anode Heat Storage Capacity | 190,000HU 140,000HU | |
Heat Storage of Tube Assembly | 1,250,000HU 1,250,000HU | |
Diagnostic Table | Film Size and Exposure Procedure | 8" × 10" |
10" × 12" | ||
11" × 14" | ||
14" × 14" | ||
Send Film Method | Film feed driven by motor; Automatic skipping | |
Range of Movement | ≥720mm ( longitudinally ) | |
≥200mm ( transversely ) | ||
≥260mm for pressure direction, Press power: 80~100N | ||
Pattern of Movement | Driven electrically | |
Filtering Grid | Fixed type; grid ratio: r=8; grid density: N=40L/cm | |
Focal distance: 70cm; Size: 14" ×14" | ||
Range of Movement | +90° ~ 0° ~ -15° | |
Pattern of Movement | Driven electrically, at a speed of about 90°/30s |
|
Range of Movement | Able to be extended 30cm at the front end | |
Pattern of Movement | Driven electrically, at a speed of about 3cm/s |
|
Radiographic Table | Tabletop Length | 2000mm |
Tabletop Width | 740mm | |
Tabletop Height | 658mm | |
Tabletop Movement | Longitudinal: 1200mm; Lateral: 200mm | |
Strut Movement Along Table (Longitudinal) | 1200mm | |
DIS Travel while X-ray Tube Assembly Vertically Moving up and down |
1100mm | |
Rotation Range of X-ray Tube Around Lateral Arm | +120° ~ -120° | |
Strut Rotation Range | +180° ~ -180° | |
Tabletop Locking | electromagnetically locking, brake pressure ≥100N |
|
Tabletop Locking Control | footswitch (normally closed) | |
Bucky Vibration Mode | Fixed type | |
Focus | fo=100 | |
Grid Size | 14" X 17" ( 356mm × 432mm ) | |
Film Loaded in Bucky | Max 14" × 17" | |
Longitudinal Travel of Bucky | 500mm | |
Bucky Locking | electromagnetically locking, brake pressure ≥100N |
|
Image System | Working Mode | Continuous |
Scanning Ratio | 2.1 Interlaced | |
Number of Scanning Line | 625TCL | |
Number of Frame per Second | 25 | |
Aspect Ratio | 4: 3 | |
CCD Camera | 400,000 pixels CCD | |
Resolution | Horizontal Center≥800 TVL; Vertical Center ≥400 TVL |
|
Image Intensifier | Model | Thales |
Input size | 9 inch (9"/6"/4.5") | |
Resolution | 46 lp/cm | |
DQE | 65% | |
Image Processing Function | ||
Last image hold | ||
8 images storage | ||
Dynamic function | ||
Static function | ||
Digital mask circle | ||
Automatic KV control | ||
14 inch monitor 1set | ||
Collimator | XS1-2 XS1-2 | |
Mode of Adjustment | Manuel Electrically-Driven | |
Maximum Tube Voltage | 150kV 150kV | |
Radiation Field [Max SID = 65cm] | 350mm X 350mm 350mm X 350mm | |
Radiation Field [Min SID = 100cm] | 0 ≤50mm X 50mm | |
Time Limit of the Light Source | ≤60s N/A | |
Inherent Filtration | 1.5 (mmAl) N/A | |
External Dimension (L×W×H) | 250×224×250mm 212×212×223mm |