Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer

Product Details
Customization: Available
Type: Defibrillator
Certification: CE, ISO13485
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
  • Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
  • Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
  • Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
  • Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
  • Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
Find Similar Products
  • Overview
  • Product Parameters
  • Product Show
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
DM7000
Group
Adult
LCD Display
High-Resolution TFT
Waveform
Biphasic
Heart Rate Meter
20 to 300 Bpm
Sweep Speed
25mm/Sec
Optional
Etco2 & NIBP & SpO2 & Pacer
Origin
China
Production Capacity
1000 PCS/Month

Product Description

 
Product Parameters

Display
1.Screen Type: High-resolution display
2.Screen Size: 7 Inches(17.7cm) diagonally
3.Sweep Speed: 25mm/sec
4.Information: Heart Rate, Lead/pads, A;arm on/off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.


ECG Monitoring
1.Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles
2.Lead Selection: Displayed on monitor, paddles, I,II,III,AVR,AVL,AVF,V
3.ECG Size: 0.25,0.5,1,1.5.2.4cm/mV display on monitor
4.Heart Rate: 20-300BPM
5.Heart Rate Alarm: On/Off display on monitor, user-selectable
6.Smart Alarms: Beeper/voice prompts indicate shockable rhythm
 
Defibrillator
1.Waveform: Biphasic
2.Energy Display: Monitor display indicates both selected and delivered energy
3.Charge Prompt Type: Voice and visual prompts
4.Electrode Impedance Measurement Range:0-250 ohms
 
Battery
1.Type: Rechargeable, Ni-MH battery,12V
2.Operation Time: For a new, fully charged battery60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operation time with different functions.
 
SpO2 (Optional)
1.Measurement Range: 30~100%, ±2% between 80%~90%, Others ±5%
2.Alarm Range: User set high limit and low limit
3.Alarm Accuracy: ±10% withinsetting values
4.Alarm time Accuracy: less than 12 sec
 
Recorder
1.Paper: 50mm thermal
2.Speed: 12.5mm/sec,25mm/sec,50mm/sec. User-selectable 6-second delay
3.Printing Method: High-resolution, thermal array print head
4.Print-out Modes: Manual or automatic, user-configurable
On/Off Control: Front panel and paddle
5.Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge
 
Manual Mode
1.Energy Selection: Selectable at 2,5,7,10,20,30,50,70,100, 150,200,300,360 joules
2.Synchronized Mode: Synchronizes defibrillator pulse to patient's
3.R-wave. "SYNC" message displayed on monitor
 
AED Mode
1. AED Function: Auto analyze and charge ×3 with programmable auto energy level selection, screen prompts, and voice prompts
2. Shockable Rhythms: Ventricular fibrillation, Ventricular tachycardia, QRS complex wave duration
Charge Control: Control on device front panel, press key on paddle

 


Product Show
Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
 
Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer
 

 

Packaging & Shipping

Dm7000 Portable Defibrillator Monitor Aed with or Without SpO2 Pacer


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier