Nicu Incubator Infant Neonatal Isolette Incubator with Baby Mode

Product Details
Customization: Available
Type: Infant Incubator
Kind: Gynaecology
Still deciding? Get samples of US$ 1500/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Find Similar Products

Basic Info.

Model NO.
BI-90A
Group
Children
LCD Display
Without LCD Display
Classification
Infant Transport Incubator
Applications
ICU Incubator Nicu
Trolley
Yes
Skin Temperature Probe
1PC
Mode of Control
Air Mode,Baby Mode
Iris Port
Yes
Cabinet
Yes
Access Port
6(2 Iris Port)
Phototherapy Unit
No
Transport Package
Carton
Specification
with trolley
Trademark
Perlong
Origin
China
HS Code
90189090
Production Capacity
1000PCS/Month

Product Description

Incubation Medical Infant Baby Neonatal  Isolette Incubator With Blue Phototherapy Unit
 Two control modes: Air mode and baby mode controlled by micro-computer;Set temperature, air temperature, baby temperature are displayed separately;Natural air flow humidity;Inclination of bassinet is adjustable;Failure alarm indication;RS-232 connector;Oxygen input interface;Disposable skin temperature sensor is optional;BI-90AB is configured with fixed Neonate Bilirubin Phototherapy Equipment model:LED blue lightsDC motor is optionalDisposable skin temperature sensor is optional;
SpecificationPower supply: AC220V-230V/50Hz or AC110-120V/50-60HzInput power: 850VAMode of control: Air mode and baby mode controlled by micro-computerControl range of air temperature: 25ºC-37ºC (override mode: 37-39ºC)Control range of baby temperature: 34-37ºC (override mode: 37-38ºC)Accuracy of skin temperature sensor: ±0.3ºCVariability of temperature: ≤0.5ºCUniformity of temperature: ≤0.8ºC(mattress is on the horizontal position)Inclination of the bassinet: ±12°Noise inside hood: ≤55dB(A) (Environment noise≤45dB(A))
Optional: with DC motor. Noise inside hood: ≤45dB(A) (Environment noise≤35dB(A))Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.Built-in timer range: 0~9999 hrs 59min Accuracy of weight display: ±1%(equipped weighing system)
Model Standard Configuration
BI-90A Main body, mobile cabinet, temperature controller, baby compartment, I.V. pole, shelf.
BI-90AB  based on BI-90A, with Neonate bilirubin phototherapy equipment (fixed model)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier